首页> 外文会议>Power Electronics for Distributed Generation Systems (PEDG), 2012 3rd IEEE International Symposium on >All-electric wave energy converter connected in array with common DC-link for improved power quality
【24h】

All-electric wave energy converter connected in array with common DC-link for improved power quality

机译:全电波能量转换器与公共直流母线成阵列连接以提高电能质量

获取原文
获取原文并翻译 | 示例

摘要

Wave Energy Converters (WECs) with direct electric Power Take Off systems have large fluctuations in output power, and have a peak to average power ratio far above most other energy producers. Moreover, the typical average power production from a WEC is lower than that of other power plants, typically less than 1 MW. Array connection of several WECs can mitigate these shortcomings by increasing both the power output and quality. The focus of this paper is to analyze Fred. Olsen designed WEC system Bolt 2 Wavehub and the effect of expanding to a small array. The required specifications for the array geometry, the electrical configuration and the overall system are discussed and a specific array design consisting of 7 WECs is suggested as a solution and analyzed in detail. The results show that the peak to average power ratio can be reduced by a factor of 4 if the array covers a full wave length.
机译:具有直接电取力系统的波浪能转换器(WEC)输出功率波动较大,并且峰均功率比远高于大多数其他能源生产商。此外,WEC的典型平均发电量低于其他发电厂的平均发电量,通常小于1 MW。几个WEC的阵列连接可以通过增加功率输出和质量来减轻这些缺点。本文的重点是分析弗雷德。奥尔森设计了WEC系统Bolt 2 Wavehub,并将其扩展为小阵列的效果。讨论了阵列几何形状,电气配置和整个系统所需的规范,并提出了由7个WEC组成的特定阵列设计作为解决方案,并进行了详细分析。结果表明,如果阵列覆盖整个波长,则峰均功率比可以降低4倍。