首页> 外文会议>Photonic therapeutics and diagnostics VI >Near-IR Optical Properties of Canine Prostate Tissue using Oblique-Incidence Reflectometry
【24h】

Near-IR Optical Properties of Canine Prostate Tissue using Oblique-Incidence Reflectometry

机译:斜入射反射法测定犬前列腺组织的近红外光学性质

获取原文
获取原文并翻译 | 示例

摘要

Optical imaging systems utilizing near-infrared light sources such as optical coherence tomography (OCT) have recently been used for imaging the prostate gland. However, the optimal wavelength for deep imaging of the prostate has yet to be determined. The objective of this study is to determine the optimal near-infrared wavelength for OCT imaging of the prostate using a system that has the potential to be used in an in vivo model. An oblique-incidence single point measurement technique using a normal-detector scanning system was implemented to determine the absorption (μ_a) and reduced scattering coefficients (μ'_s) of fresh canine prostate tissue, ex vivo, from the diffuse reflectance profile of near-IR light as a function of source-detector distance. The effective attenuation coefficient (μ__(eff)) and optical penetration depth (OPD) were then calculated for near-IR wavelengths of 1064, 1307, and 1555 nm. A total often canine samples were used for this study. At wavelengths of 1064, 1307, and 1555 nm, the mean absorption coefficients measured 0.08 + 0.03, 0.12 + 0.04, and 0.23 + 0.09 cm~(-1), respectively. The mean reduced scattering coefficients measured 16.60 ± 0.95, 14.30 + 1.14, and 10.98 + 2.35 cm~(-1). The effective attenuation coefficients were calculated to be 2.00, 2.28, and 2.78 cm~(-1), yielding OPD's of 0.5, 0.44, and 0.36 cm at 1064, 1307, and 1555 nm. OCT imaging studies of the prostate may benefit from replacement of commonly used 1310 nm broadband light sources with 1064 nm sources.
机译:利用近红外光源的光学成像系统,例如光学相干断层扫描(OCT),最近已用于对前列腺进行成像。但是,尚未确定用于前列腺深层成像的最佳波长。这项研究的目的是使用可能在体内模型中使用的系统,确定用于OCT前列腺成像的最佳近红外波长。实施了使用正常检测器扫描系统的斜入射单点测量技术,通过离体的近距离漫反射光谱确定离体新鲜犬前列腺组织的吸收(μ_a)和降低的散射系数(μ'_s)。红外光作为源探测器距离的函数。然后针对1064、1307和1555 nm的近红外波长计算有效衰减系数(μ__(eff))和光穿透深度(OPD)。总共经常将犬样本用于该研究。在1064、1307和1555 nm波长处,平均吸收系数分别为0.08 + 0.03、0.12 + 0.04和0.23 + 0.09 cm〜(-1)。平均降低的散射系数测得为16.60±0.95、14.30 + 1.14和10.98 + 2.35 cm〜(-1)。有效衰减系数经计算为2.00、2.28和2.78 cm〜(-1),在1064、1307和1555 nm处产生的OPD分别为0.5、0.44和0.36 cm。前列腺的OCT成像研究可能会受益于用1064 nm光源代替常用的1310 nm宽带光源。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号