【24h】

High-dose-rate pulse x-ray detection using a multipixel photon counter

机译:使用多像素光子计数器的高剂量率脉冲X射线检测

获取原文
获取原文并翻译 | 示例

摘要

Detection of high-dose-rate pulse x-rays from a samarium plasma flash x-ray generator utilizing a multipixel photon counter is described. Monochromatic K-series characteristic x-rays are detected by a plastic scintillator, and fluorescent lights are lead to the photon counter through a 10-m-length plastic fiber. The reverse bias was 70.0 V, and x-ray outputs were recorded by a digital storage scope. The samarium plasma flash x-ray generator is useful for performing high-speed enhanced K-edge angiography using cone beams because K-series characteristic x-rays from the samarium target are absorbed effectively by iodine-based contrast media. In the flash x-ray generator, a 150 nF condenser is charged up to 80 kV by a power supply, and flash x-rays are produced by the discharging. Since the electric circuit of the high-voltage pulse generator employs a cable transmission line, the high-voltage pulse generator produces twice the potential of the condenser charging voltage. At a charging voltage of 80 kV, the estimated maximum tube voltage and current are approximately 160 kV and 40 kA, respectively. When the charging voltage was increased, the K-series characteristic x-ray intensities of samarium increased. Bremsstrahlung x-ray intensity rate decreased with increasing the charging voltage, and K lines were produced with a charging voltage of 80 kV. The x-ray pulse widths were approximately 100 ns, and the time-integrated x-ray intensity had a value of approximately 500 μGy at 1.0 m from the x-ray source with a charging voltage of 80 kV. Angiography was performed using a filmless computed radiography (CR) system and iodine-based contrast media. In the angiography of nonliving animals, we observed fine blood vessels of approximately 100 μm with high contrasts.
机译:描述了利用多像素光子计数器从from等离子体闪光x射线发生器中检测高剂量率脉冲x射线。塑料闪烁体检测到单色K系列特征X射线,荧光灯通过10米长的塑料纤维引到光子计数器。反向偏置为70.0 V,并且数字存储示波器记录了X射线输出。 plasma等离子体闪光X射线发生器可用于使用锥形束进行高速增强的K边缘血管造影,因为来自target靶的K系列特征X射线被基于碘的造影剂有效吸收。在闪光X射线发生器中,通过电源将150 nF的聚光器充电至80 kV,并且通过放电产生闪光X射线。由于高压脉冲发生器的电路采用电缆传输线,因此高压脉冲发生器产生的电容是电容器充电电压的两倍。在80 kV的充电电压下,估计的最大管电压和电流分别约为160 kV和40 kA。当充电电压增加时,the的K系列特征X射线强度增加。 ms致辐射的x射线强度率随着充电电压的增加而降低,并且以80kV的充电电压产生K线。 X射线脉冲宽度约为100 ns,并且距X射线源1.0 m处的时间积分X射线强度值约为500μGy,充电电压为80 kV。使用无胶片计算机X线照相(CR)系统和基于碘的造影剂进行血管造影。在无生命动物的血管造影中,我们观察到约100μm的细血管具有高对比度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号