首页> 外文会议>PCI 60th anniversary 2014 convention and national bridge conference >SPLICED CONNECTIONS FOR ADJACENT PRECAST MEMBER BRIDGES USING ULTRA AND VERY HIGH PERFORMANCE CONCRETE
【24h】

SPLICED CONNECTIONS FOR ADJACENT PRECAST MEMBER BRIDGES USING ULTRA AND VERY HIGH PERFORMANCE CONCRETE

机译:使用超高性能混凝土的临近预制桥梁的特殊连接

获取原文
获取原文并翻译 | 示例

摘要

Spliced connections in the longitudinal joints of bridges with adjacent precast members are investigated as an alternative to the current grouted shear key connection. The minimum splice lengths are determined for No. 4 and No. 6 bars using fiber reinforced ultra and very high performance concretes (UHPC and VHPC) as connection materials. The minimum splice length is determined experimentally using simply supported reinforced concrete beam specimens with tension splices formed within a pocket filled with the fiber reinforced connection material. The test results are verified using a strain compatibility analysis of the beam specimens to confirm the yielding of tension steel. The experimental and analytical results show that the minimum splice length with No. 4 bars is 4 in. and that with No. 6 bars is 6 in. The conclusions made in this research show that UHPC and VHPC can be used to reduce the length of tension splices and these connections can be applied in longitudinal joints of adjacent precast member bridges.
机译:研究了桥梁纵向接头中与相邻预制构件的拼接连接,以替代当前灌浆的剪切键连接。使用纤维增强的超高性能混凝土(UHPC和VHPC)作为连接材料,确定4号和6号钢筋的最小拼接长度。最小接头长度是通过使用简单支撑的钢筋混凝土梁试样通过实验确定的,该试样带有在纤维增强连接材料填充的袋内形成的张力接头。使用梁样本的应变相容性分析来验证测试结果,以确认抗拉钢的屈服强度。实验和分析结果表明,No。4 bar的最小拼接长度为4 in。,No。6 bar的最小拼接长度为6 in。该研究得出的结论表明,UHPC和VHPC可以用于减小UP的长度。张力接头和这些连接可以应用在相邻预制构件桥的纵向接头中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号