The Air-acetylene Flame Atomic Absorption Spectrometry (FAAS) was used to measure Sr content in Mg-Sr Alloys. The experiment conditions including acetylene flow rate, measurement height, flame wavelength were studied and the disturbing factors were discussed. It was found that, as dissolution agent of alloys and LaCl3 as the deionization agent and flame wavelength being 460.7nm, the detection limits is 1.16mg/L and the relative standard deviations is less than 0.3% and the recovery rates of Sr is more than 95%. The advantages of this method were summarized as: high sensitivity and precision, low chemistry disruption, good selectivity, good recurrence characteristics of the measuring conditions. The method is suitable for the control analysis and sample-system analysis of determination Sr content in the Mg-Sr Master Alloys.
机译:空气乙炔火焰原子吸收光谱法(FAAS)用于测量Mg-Sr合金中的Sr含量。研究了乙炔流量,测量高度,火焰波长等实验条件,并讨论了干扰因素。结果发现,作为合金的溶解剂,LaCl3作为去离子剂,火焰波长为460.7nm,检出限为1.16mg / L,相对标准偏差小于0.3%,Sr的回收率大于0.2%。 95%。该方法的优点概括为:灵敏度高,精密度低,化学干扰小,选择性好,测量条件的重复性好。该方法适用于Mg-Sr中间合金中Sr含量测定的控制分析和样品系统分析。