首页> 外文会议>Optical tomography and spectroscopy of tissue IX >First in vivo spectral characterization of breast up to 1300 nm
【24h】

First in vivo spectral characterization of breast up to 1300 nm

机译:首次对高达1300 nm的乳房进行体内光谱表征

获取原文
获取原文并翻译 | 示例

摘要

Spectral measurements were performed from 900 to 1300 nm, using a fully automated set-up for time domain optical spectroscopy. Spectrally selected picosecond pulses emitted from a supercontinuum fiber source were used for illumination. The detection of re-emitted pulses was achieved using a photomultiplier tube with InP/InGaAsP photocathode, followed by a PC board for time-correlated single photon counting.To allow the estimate of tissue composition at long wavelengths, the optical characterization of collagen type I powder was extended up to 1300 nm. A marked absorption peak was detected around 1200 nm, which could prove useful for collagen quantification from in vivo optical data.In vivo spectral measurements of breast tissue were performed for the first time from 900 to 1300 nm in reflectance geometry. The sensitivity of the detector was very low above 1200 nm, still it allowed us to reveal a long-wavelength range (1000-1300 nm) potentially interesting for applications. A dominant absorption peak is present around 1200 nm. All major tissue constituents (i.e., water, lipid, and collagen) contribute to it. Thus, it is potentially interesting for the assessment of tissue composition, but it might cause exceeding attenuation in some practical cases. However, slightly shorter wavelengths (i.e. 1100-1150 nm) corresponding to the raising edge of the peak, might allow an accurate estimate of tissue composition, with the advantage of much lower attenuation.
机译:使用用于时域光谱的全自动装置在900至1300 nm范围内进行光谱测量。从超连续谱纤维源发出的光谱选择的皮秒脉冲用于照明。使用具有InP / InGaAsP光电阴极的光电倍增管和随后的PC板进行时间相关的单光子计数,可以检测到重新发射的脉冲。为了估算长波长的组织组成,I型胶原的光学表征粉末扩展到1300 nm。在1200 nm附近检测到明显的吸收峰,这可能对从体内光学数据中进行胶原蛋白定量很有用。首次在900至1300 nm的反射几何范围内进行了乳腺组织的体内光谱测量。探测器的灵敏度在1200 nm以上非常低,它仍然使我们能够揭示可能对应用感兴趣的长波长范围(1000-1300 nm)。在1200 nm附近存在一个主要的吸收峰。所有主要的组织成分(即水,脂质和胶原蛋白)都对其起作用。因此,对于组织组成的评估可能是令人感兴趣的,但是在某些实际情况下可能导致过度衰减。然而,对应于峰的上升沿的稍短的波长(即1100-1150nm)可以允许对组织组成的精确估计,其衰减要低得多。

著录项

  • 来源
    《Optical tomography and spectroscopy of tissue IX》|2011年|p.78962L.1-78962L.4|共4页
  • 会议地点 San Francisco CA(US)
  • 作者单位

    Politecnico di Milano - Dipartimento di Fisica, Piazza Leonardo da Vinci 32, 20133 Milano, Italy,Consiglio Nazionale delle Ricerche, Istituto di Fotonica e Nanotecnologie, Piazza Leonardo da Vinci 32, 20133 Milano, Italy;

    Politecnico di Milano - Dipartimento di Fisica, Piazza Leonardo da Vinci 32, 20133 Milano, Italy;

    Politecnico di Milano - Dipartimento di Fisica, Piazza Leonardo da Vinci 32, 20133 Milano, Italy;

    Politecnico di Milano - Dipartimento di Fisica, Piazza Leonardo da Vinci 32, 20133 Milano, Italy,Consiglio Nazionale delle Ricerche, Istituto di Fotonica e Nanotecnologie, Piazza Leonardo da Vinci 32, 20133 Milano, Italy;

    Politecnico di Milano - Dipartimento di Fisica, Piazza Leonardo da Vinci 32, 20133 Milano, Italy,Consiglio Nazionale delle Ricerche, Istituto di Fotonica e Nanotecnologie, Piazza Leonardo da Vinci 32, 20133 Milano, Italy;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 医用物理学;
  • 关键词

    absorption; breast; tissue spectroscopy;

    机译:吸收乳房;组织光谱学;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号