We report on the development of an optical-fiber-based diagnostic instrument to determine the local optical properties of a turbid media. The system relies on making differential diffuse reflection measurements. We present a method to correct for the variations in the spectral characteristics of the two spectrometers. We also introduce a novel method to evaluate the differential reflectance by encoding a relative wavelength sensitivity constant into the signal processing to account for differences in the spectral sensitivity between spectrometers. This method allows us to record differential reflectance without needing to make additional reference measurements before an experiment to account for spectral variation of the lamp.
机译:我们报告了一种基于光纤的诊断仪器的开发情况,该仪器可确定混浊介质的局部光学特性。该系统依赖于进行差分漫反射测量。我们提出一种校正两个光谱仪光谱特性变化的方法。我们还介绍了一种新颖的方法,通过将相对波长灵敏度常数编码到信号处理中来解决光谱仪之间光谱灵敏度的差异,从而评估差分反射率。这种方法使我们能够记录差异反射率,而无需在进行实验以解决灯的光谱变化之前进行其他参考测量。