The method of null test is widely used for testing an aspheric mirror. During optical manufacturing process, the mirror has to be moved up and down for testing and fabricating. Because the alignment of null test is difficult and time costing, the efficiency of making aspheric mirror is decreased greatly. In order to solve the problem, we developed a software based on polynomial fitting to calculate the misalignment parameters. By using the software and computer numeric controlled adjusting equipments, the efficiency of testing is increased and the accuracy of test has reached up to λ/40 RMS where λ equals to 632.8nm, which has fulfilled the demand of the designer.
机译:无效测试的方法被广泛用于测试非球面镜。在光学制造过程中,必须上下移动镜子以进行测试和制造。由于无效测试的对准困难并且费时,因此非球面镜的制造效率大大降低。为了解决该问题,我们开发了基于多项式拟合的软件来计算失准参数。通过使用软件和计算机数控调节设备,提高了测试效率,测试精度达到了λ/ 40 RMS,其中λ等于632.8nm,满足了设计者的需求。