VALIDATION ANALYSIS OF BURNUP CODE MVP-ORBURN USING THE SFCOMPO DATABASE

机译:使用SFCOMPO数据库验证组合代码MVP-ORBURN的有效性

获取原文
获取原文并翻译 | 示例

摘要

A series of burnup calculations was conducted for typical post irradiation experimental data prepared in SFCOMPO using JNES's MVP-ORBURN code, which is a coupling codes of MVP-Ⅱ and ORIGEN2. The analyzed cases cover a wide range of data including four pressurized water reactors (PWRs) and three boiling water reactors (BWRs). As long as the post-irradiation composition of major actinides applied in the Level 1 burnup credit are concerned, the calculation results of end of cycle (EOC) compositions obtained using the JENDL-3.3 nuclear data library showed a good agreement within a range of 10% discrepancy between the calculations and the experiments. Consequently, the code system is found to be sufficiently applicable to burnup credit evaluations.
机译:使用JNES的MVP-ORBURN代码(是MVP-Ⅱ和ORIGEN2的耦合代码),对在SFCOMPO中准备的典型辐照后实验数据进行了一系列的燃耗计算。分析的案例涵盖了广泛的数据,包括四个压水堆(PWR)和三个沸水堆(BWR)。只要涉及在1级燃耗信用额中应用的主要act系元素的辐照后成分,使用JENDL-3.3核数据库获得的周期结束(EOC)成分的计算结果在10的范围内显示出良好的一致性。计算与实验之间的差异百分比。因此,发现该代码系统足够适用于燃尽信用评估。

著录项

  • 来源
  • 会议地点 Richland WA(US)
  • 作者单位

    Nuclear Safety Analysis and Evaluation Office, Nuclear Energy System Safety Division, Japan Nuclear Energy Safety Organization (JNES) TOKYU REIT Toranomon Bldg., 3-17-1, Tomnomon, Minato-ku, Tokyo, 105-0001, JAPAN;

    rnNuclear Safety Analysis and Evaluation Office, Nuclear Energy System Safety Division, Japan Nuclear Energy Safety Organization (JNES) TOKYU REIT Toranomon Bldg., 3-17-1, Tomnomon, Minato-ku, Tokyo, 105-0001, JAPAN;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 X946;
  • 关键词

  • 入库时间 2022-08-26 14:11:59