Miami Thrice; Lanzo, HJ3, and Carbon Fiber Reinforced Polymer, Preempt Catastrophic Line Breaks with Emergency Repairs in Dade County 54-inch and 48-inch PCCP for Drinking Water using (CFRP)

机译:迈阿密三次Lanzo,HJ3和碳纤维增强聚合物通过使用(CFRP)在达德县54英寸和48英寸PCCP饮用水中进行紧急修复,抢占了灾难性的线路中断

获取原文
获取原文并翻译 | 示例

摘要

One of the more compelling stories being told within today's rehabilitation framework is that of how we are dealingrnwith our aging Potable Water Infrastructure. The existence of deteriorated Large Diameter Pre-stressed Cylinderrnpipes (PCCP) in water transmission lines throughout the United States represents a liability shared by manyrnmunicipalities. A vast inventory of late 1970’s and early 1980’s pipe are suspect due to corrosion and pre-stressingrnwire breaks Our most prolific water authorities and municipalities have entered into a race against time to preventrncatastrophic failure and shutdown from occurring in these water transmission lines. A path being followed is to firstrnperform a condition assessment, and then to prioritize a repair schedule for deteriorated pipe. Carbon FiberrnReinforced Polymer (CFRP) systems have increasingly become a reliable technology utilized for internal andrnexternal rehabilitation of PCCP and Reinforced Concrete Pipe (RCP). The use of CFRP has proven beneficial to therndrinking water industry due to the fact that it can be field applied, avoiding the need for expensive and disruptivernexcavations. The integrity of CFRP repairs for drinking water pipe relies on: an accurate condition assessment ofrnthe host pipe, a transfer of the assessment and design information from the owner to a qualified engineer, arnspecification that requires qualified and experienced CFRP manufacturers, designers, installers, and inspectors. Thisrnpaper shall present two separate projects performed for Miami Dade WASD where one such 54-inch and a 48-inchrnLock Joint Cylinder pipe system were first non-destructively identified as being defective, then rehabilitated usingrnthe HJ3 manufactured CFRP repair system installed by Lanzo Trenchless Technologies.
机译:在当今的恢复框架内,最令人信服的故事之一就是我们如何处理老化的饮用水基础设施。遍布美国的输水管道中存在劣化的大直径预应力圆柱管(PCCP),这是许多市政当局共同承担的责任。由于腐蚀和预应力钢丝断裂,人们怀疑1970年代末和1980年代初期有大量的管道。我们最多产的水务部门和市政当局都在争夺时间,以防止这些输水管道发生灾难性故障和停工。遵循的路径是首先执行状态评估,然后优先确定已损坏管道的维修计划。碳纤维增强聚合物(CFRP)系统已逐渐成为一种可靠的技术,用于PCCP和钢筋混凝土管(RCP)的内部和外部修复。由于CFRP可以现场使用,从而避免了对昂贵和破坏性开挖的需求,因此事实证明CFRP对饮用水行业有利。 CFRP维修饮用水管道的完整性取决于:对主机管道的准确状态评估,评估和设计信息从拥有者到合格工程师的转移,技术规格要求合格且经验丰富的CFRP制造商,设计师,安装商和检查员。本文将介绍为迈阿密达德WASD执行的两个单独的项目,其中首先无损地确定其中一个这样的54英寸和48英寸锁紧式接合管系统是有缺陷的,然后使用由Lanzo Trenchless Technologies安装的HJ3制造的CFRP维修系统进行修复。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号