首页> 外文会议>NOISE-CON 11;National conference on noise control engineering >Examining different retrofit solutions to enhance airborne sound transmission loss in wood frame wall construction.
【24h】

Examining different retrofit solutions to enhance airborne sound transmission loss in wood frame wall construction.

机译:检查不同的改造解决方案,以提高木结构墙体建筑中的空气传播声损耗。

获取原文

摘要

Through laboratory testing we were able to compare different retrofit solutions to increasethe sound transmission class (STC) rating of a base wall assembly. The base assemblyconsisted of a nom 2×4 wood stud spaced 16”OC, R13 insulation (3.5”) and 1 layer of 5/8”Type X gypsum wallboard on source and receiving side. Four retrofit solutions were usedincluding; 1 layer of 5/8” Type X gypsum wallboard, 1 layer of Quiet Rock QR528, 1 layerof Type X gypsum wallboard with Green Glue, 1 layer of Type X gypsum wallboard withGenieClipTM sound isolation clips.
机译:通过实验室测试,我们能够比较不同的翻新解决方案,以提高底墙组件的传声等级(STC)。底座组件由标称2×4的木质双头螺栓组成,间隔为16“ OC,R13绝缘材料(3.5”)和源和接收侧的1层5/8“ X型石膏墙板。使用了四种翻新解决方案,其中包括: 1层5/8英寸X型石膏墙板,1层Quiet Rock QR528,1层带绿色胶水的X型石膏墙板,1层具有GenieClipTM隔音夹的X型石膏墙板。