【24h】

CATAPHORESIS PHENOMENON OF FLUORESCENT LAMPS WITH HF ELECTRONIC BALLASTS

机译:高频电子镇流器荧光灯的催化现象

获取原文
获取原文并翻译 | 示例

摘要

The cataphoresis phenomenon of T8-4ft FL lamp systems with HF ballasts was analyzed in relation to two definitive parameters; the coldest tube wall temperature T_c and superimposed DC voltage component V_(DC). This has clarified the critical cataphoresis outbreak conditions, given by the equation V_(DC)= 0.56 T_c - 43. In addition, through experiments on the lamp burning hours to the cataphoresis outbreak, the ballast design requirement of less than V_(DC) 2 V is proposed as an actual suppression measure against the cataphoresis phenomenon in the fields.
机译:结合两个定性参数,分析了带有高频镇流器的T8-4ft FL灯系统的电泳现象。最冷的管壁温度T_c和叠加的直流电压分量V_(DC)。这就澄清了由公式V_(DC)= 0.56 T_c-43给出的关键的电泳爆发条件。此外,通过对达到电泳爆发的灯燃烧时间进行实验,镇流器的设计要求小于V_(DC)2提出将V作为对现场中的电泳现象的实际抑制措施。