For Xiang Jia Ba hydro power plant, the biggest aircooled hydro generator with an output of 890 MVA will be installed. The machine, within the scope of supply for ALSTOM at Right Bank, is designed with a 23 kV stator winding which finally allows an optimized electrical design of the entire machine considering the project specific speed and output. This paper will introduce the design, the manufacturing and the acceptance test of the aircooled 23kV stator bars. The complete acceptance tests of the bars show that the insulation system has good properties on thermal-electric aging, breakdown capability, dielectric losses and corona protection. This is a quite valuable reference to design stator winding at higher voltage level for in large machine up to 1000MW for example.
机译:对于香家坝水电厂,将安装最大的风冷水力发电机,其输出为890 MVA。该机器在Right Bank的ALSTOM供货范围内,采用23 kV定子绕组设计,最终可以根据项目的特定速度和输出对整个机器进行优化的电气设计。本文将介绍风冷的23kV定子棒的设计,制造和验收测试。棒材的完整验收测试表明,绝缘系统在热电老化,击穿能力,介电损耗和电晕防护方面具有良好的性能。对于在例如高达1000MW的大型机器中设计更高电压等级的定子绕组,这是一个非常有价值的参考。