Side-by-side operation of four membrane pilot tertiary treatment systems was conducted at thernSacramento Regional Wastewater Treatment Plant (SRWTP) from May through November ofrn2005. Pilot units were supplied with secondary effluent from the SRWTP. A pretreatment pilotrnunit was operated in front of the membranes during the last two months of the test program torndetermine if pretreatment could significantly enhance membrane performance.rnPerformance objectives for the testing included:rn1. Meet California Title 22 turbidity standards for reclaimed waterrn2. Do not exceed vendor guidelines for operating trans-membrane pressure (TMP)rn3. Operate at least 30 continuous days between membrane chemical cleaning cyclesrn4. Operate at least 24 hours between maintenance cleaning cyclesrnWith the secondary effluent feed water, all four membrane vendors met the minimumrnrequirement for 30 days of continuous operation at a constant flux. Proven flux rates variedrnsignificantly. In general, membrane effluent quality was very good, with effluent turbidities wellrnbelow the 0.20 NTU California Title 22 turbidity standard at all four pilots. Pretreatment hadrnminimal benefit on membrane flux rates, and in some cases caused problems with membranernfouling due to coagulant / polymer carryover from the pretreatment unit.rnPredesign for a 9-MGD membrane facility at SRWTP is underway. Based on the pilot testrnresults, two of the four membranes that were piloted remain under consideration for the newrnfacility.
机译:2005年5月至11月在萨克拉曼多地区废水处理厂(SRWTP)进行了四个膜中试三级处理系统的并排操作。向试点单位提供了来自SRWTP的二次污水。在测试程序的最后两个月中,对膜前进行了一个预处理中试单元,以确定预处理是否可以显着提高膜的性能。rn该测试的性能目标包括:rn1。达到再生水rn2的加利福尼亚标题22浊度标准。不要超出供应商操作跨膜压力(TMP)rn3的准则。在膜化学清洗周期之间至少要连续运行30天4。在维护清洗周期之间至少要运行24小时。使用二级废水给水,所有四个膜供应商均应在恒定流量下连续运行30天达到最低要求。公认的通量率变化很大。总的来说,膜废水的质量非常好,所有四个试点的废水浊度均低于0.20 NTU加州Title 22浊度标准。预处理对膜通量率的益处最小,并且在某些情况下,由于预处理单元中的凝结剂/聚合物残留而导致膜结垢问题。正在进行SRWTP的9-MGD膜设施的预设计。根据试验结果,被试验的四个膜中的两个仍在考虑用于新设施。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号