This paper presents a new model to compute the degree of unbalanced in case of self-excited induction generator. Model is based upon the symmetrical component approach. Shunt magnetizing reactance of negative sequence equivalent circuit, generally omitted by the researchers is accounted in the proposed model. Simulated results as obtained are used to analyze the effect of variation in load and excitation capacitance on the degree of unbalance.
机译:本文提出了一种新模型,用于计算自激感应发电机情况下的不平衡程度。模型基于对称分量方法。负序等效电路的并联励磁电抗通常被研究人员所忽略,被认为是提出的模型。所获得的模拟结果用于分析负载和励磁电容变化对不平衡程度的影响。