In this paper, a non-salient-pole and salient-pole synchronous generator with static eccentricity fault are simulated using finite element analysis. Different severities of the static eccentricity fault are considered and its effect on flux density, voltage and current is shown and compared with the healthy generator. It was observed that the air gap magnetic flux pattern in the faulty generator is asymmetrical leading to harmonics in the flux and voltage signals. The indexes for fault detection are introduced based on the no-load voltage and full load current signals. These indexes are sensitive to the occurrence of the fault and can be used to detect the static eccentricity fault.
机译:本文采用有限元分析模拟了具有静偏心故障的非凸极和俯仰极同步发电机。 考虑静偏心故障的不同严重性,并与健康发生器相比,示出了其对磁通密度,电压和电流的影响。 观察到,故障发生器中的气隙磁通量图案是不对称的,导致通量和电压信号中的谐波。 基于无负载电压和全负载电流信号引入故障检测索引。 这些索引对故障发生敏感,并且可用于检测静态偏心故障。