首页> 外文会议>IEEE International Future Energy Electronics Conference >Partial Discharge in Medium-voltage Motor Winding Insulation Exposed to Two-level PWM Waveforms
【24h】

Partial Discharge in Medium-voltage Motor Winding Insulation Exposed to Two-level PWM Waveforms

机译:局部放电在中压电动机绕组绝缘暴露于两级PWM波形

获取原文

摘要

Medium-voltage motor systems with adjustable- speed drives are employed in a wide range of applications. The adoption of medium-voltage Silicon Carbide (SiC) devices in motor drives can improve motor system’s efficiency, power density, and dynamic response. But the high switching dv/dt (short rise time) produced by SiC devices increases the stress on the motor winding insulation and leads to partial discharges. This paper studies the partial discharge in the medium-voltage motor winding subjected to two-level PWM waveforms produced by medium-voltage SiC devices. Partial discharge inception voltages (PDIVs) and repetitive partial discharge inception voltages (RPDIVs) of the motor winding at various rise time, switching frequencies and modulation index are tested. Statements on PD behaviors are analyzed based on the test results.
机译:具有可调节速度驱动器的中压电动机系统在各种应用中使用。采用电动机驱动器中的中压碳化硅(SiC)器件可以提高电动机系统的效率,功率密度和动态响应。但是由SiC器件产生的高开关DV / DT(短上升时间)增加了电动机绕组绝缘体上的应力并导致部分放电。本文研究了由中压SiC器件产生的两级PWM波形的中压电动机绕组中的局部放电。测试在各种上升时间,开关频率和调制指数的电动机绕组的局部放电初始电压(PDIVS)和重复的局部放电成立电压(RPDIV)。根据测试结果分析了PD行为的陈述。