首页> 外文会议>IEEE Pulsed Power Plasma Science >Study on aging characteristics of DC transmission line arrester considering impact load
【24h】

Study on aging characteristics of DC transmission line arrester considering impact load

机译:考虑冲击载荷的直流输电线路避雷器老化特性研究

获取原文

摘要

Metal oxide arrester (MOA) is the main equipment to limit overvoltage in power system. It has been widely used in UHVDC project in China. The UHVDC system has longer deliver distance. Under the influence of various external factors, the state characteristic parameters of MOA will change and its performance will decline, which is called the aging problem. Unlike the arrester in AC system whose continuous operating voltage is power frequency voltage, the aging of MOA resistors in DC system is more complicated. Based on a ±1100kV UHVDC system in China, this paper studies voltage load waveforms of transmission line arrester in UHVDC system under different operating conditions, and analyzes its amplitude by mathematical methods. Based on simulation, the impedance characteristics and power consumption characteristics of DC line MOA proportional components under multi-factors were studied. Considering the influence of impact load, the long-term integrated DC aging characteristics of MOA were studied. The comprehensive aging test results show that during the aging test, the DC reference voltage of the mainstream formula has an increasing trend, which increases by a maximum of 6.05%; the DC leakage current shows a decreasing trend with a maximum reduction of 76%; the power loss shows a decreasing trend with a maximum of 71.4%. The AC reference voltage shows an increasing trend. The full current, resistive fundamental wave, and third harmonic show a decreasing trend. The capacitance and tanδ decrease slightly, and the residual voltage does not change significantly. The influence of different impact loads on DC aging of MOV from the most to the least is: square wave>lightning wave>high current.
机译:金属氧化物避雷器(MOA)是限制电力系统过电压的主要设备。它已广泛应用于中国的UHVDC项目。 UHVDC系统具有较长的距离距离。在各种外部因素的影响下,MOA的状态特征参数将改变,其性能下降,称为老化问题。与AC系统中的避雷器不同,其连续工作电压是功率频率电压,DC系统的MOA电阻老化更复杂。基于中国的±1100kV UHVDC系统,本文在不同的运行条件下研究了UHVDC系统中传输线避雷器的电压负荷波形,并通过数学方法分析其幅度。基于模拟,研究了多因素DC线MOA比例分量的阻抗特性和功耗特性。考虑到冲击载荷的影响,研究了MOA的长期集成直流老化特征。综合衰老试验结果表明,在老化测试期间,主流配方的直流参考电压具有越来越大的趋势,最大增加了6.05%;直流泄漏电流显示出降低趋势,最大减少76%;功率损失显示趋势的降低,最高可达71.4%。交流参考电压显示出越来越大的趋势。全电流,电阻基波和三次谐波表明趋势降低。电容和Tanδ略微降低,并且残余电压不会显着变化。不同冲击载荷对最小的影响对MOV的直流老化的影响是:方波>雷波>高电流。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号