This paper describes how the Philadelphia Water Department analyzes performance of its green stormwater infrastructure systems using post-construction monitoring data. The required level of runoff and combined sewer system performance is determined by an agreement between the Philadelphia Water Department and the Pennsylvania Department of Environmental Protection. Requirements include the average annual combined sewer overflow volume permissible, the minimum degree of capture and treatment of wet weather flows, and pollutant loads. These city-scale requirements have been translated to the site level and incorporated in green infrastructure design criteria. The combined sewer overflow volume reduction is linked to a stormwater storage volume and allowable release rate that allow any given site to meet city-wide performance objectives on a unit-area basis. Removal of pollutants occurs through infiltration, filtration, and settling processes in green infrastructure systems. Any flow remaining after infiltration is conveyed to a wastewater treatment facility.
机译:本文介绍了费城水部门如何使用施工后监测数据分析其绿色雨水基础设施系统的性能。所需水平的径流和组合的下水道系统性能是由费城水部门和宾夕法尼亚州环保部之间的协议决定的。要求包括允许的平均年度下水道溢出量,捕获和治疗湿天气流动的最低程度和污染物载荷。这些城市规模要求已转化为站点级别,并在绿色基础设施设计标准中纳入。组合的下水道溢出量减少与雨水储存量和允许任何给定场地的允许释放速率相关联,以便在单位面积基础上满足城市范围的性能目标。通过在绿色基础设施系统中的渗透,过滤和沉降过程中去除污染物发生。渗透后剩余的任何流动都被传送到废水处理设施。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号