The Grid Friendly™ Appliance (GFA) controller, developed at Pacific Northwest National Laboratory, was originally designed to autonomously switch off appliances by detecting under-frequency events. In this paper, the feasibility of using the GFA controller to provide primary frequency response is investigated. In particular, the impacts of an important design parameter, i.e., curtailing frequency threshold, on the primary frequency response are carefully analyzed for different situations. In the normal situation, the current method of selecting curtailing frequency thresholds for GFAs is found to be insufficient to guarantee the desired performance especially when the frequency deviation is shallow. In the extreme situations, the power reduction of online GFAs could be so excessive that it can even impact the system frequency negatively. As the first step towards the efforts to make GFAs suitable for providing primary frequency response, the existing controller design is improved by modifying the strategy of selecting curtailing frequency thresholds to ensure the effectiveness of GFAs in the normal situation.
机译:太平洋西北国家实验室开发的Grid Friendly™设备(GFA)控制器最初旨在通过检测低频事件自动关闭设备。在本文中,研究了使用GFA控制器提供初级频率响应的可行性。特别地,针对不同情况仔细分析了重要设计参数即缩减频率阈值对主频率响应的影响。在正常情况下,发现为GFA选择缩减频率阈值的当前方法不足以保证所需的性能,特别是当频率偏差较浅时。在极端情况下,在线GFA的功耗降低可能会过大,甚至可能对系统频率产生负面影响。作为努力使GFA适用于提供主频率响应的第一步,通过修改选择缩减频率阈值的策略以确保GFA在正常情况下的有效性,改进了现有的控制器设计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号