首页> 外文会议>World Renewable Energy Congress >DOUBLE SKIN FACADE'S EFFECTS ON HEAT LOSS OF OFFICE BUILDINGS IN ISTANBUL
【24h】

DOUBLE SKIN FACADE'S EFFECTS ON HEAT LOSS OF OFFICE BUILDINGS IN ISTANBUL

机译:双重皮肤外观对伊斯坦布尔办公楼的热量丧失的影响

获取原文
获取外文期刊封面目录资料

摘要

Double skin facade has great effect on building energy demand. In this research, a single skin and a double skin office building's heat loss were compared to show the double skin's effect on building energy demand. Double skin facade in office building has not been applied in Istanbul and that is why this research aims to show the basic effects of double skin facade, if it would be applied. A new method is used in double skin facade's heat loss calculation The method is formed of a modified step, which is the modification of the method developed by B. Todorovic, and an additional step for the time dependent heat transfer calculations. In the first step, inter-space temperature calculated. In the second step, inter-space temperatures, which is calculated in the previous step, are assumed as outdoor temperature and heat transfer through inner skin's components calculated in unsteady condition. Temperature estimation method here is adapted to the heat loss of step-by-step hourly calculation. The new method developed in the research is applied on an office building in Istanbul assuming that it would be renovated with double skin facade. Calculations have been made for the average climatic conditions of January, which is representing winter period in Istanbul. According to results of this application study single skin office building's heat loss is 40% is higher than that of double skin office building.
机译:双皮肤立面对建筑能源需求有很大影响。在这项研究中,比较了单一的皮肤和双重肌肤办公大楼的热量损失,以显示对建筑能源需求的双重皮肤的影响。办公楼中的双皮肤立面尚未在伊斯坦布尔应用,这就是为什么这项研究旨在显示双皮肤立面的基本效果,如果它将应用。一种新方法用于双皮外立面的热损失计算方法,该方法由改进的步骤形成,该方法是由B. Todorovic开发的方法的修改,以及用于时间依赖传热计算的附加步骤。在第一步中,计算间空间温度。在第二步中,假设在前一步中计算的空间温度是通过在不稳定状态下计算的内皮肤的内部皮肤组件的户外温度和热传递。这里的温度估计方法适用于逐步计算的热量损失。该研究中开发的新方法应用于伊斯坦布尔的办公大楼,假设它将与双皮立面一起翻新。已经为1月的平均气候条件进行了计算,该条件是代表伊斯坦布尔的冬季。根据本申请的结果,研究单一的皮肤办公大楼的热量损失是40%高于双皮办公大楼的热量损失。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号