首页> 外文会议>International Specialty Conference on Cold-Formed Steel Structures >Strength of Cold-Formed Steel Clip Angle in Combined Bending and Shear Loading
【24h】

Strength of Cold-Formed Steel Clip Angle in Combined Bending and Shear Loading

机译:结合弯曲和剪切装载中冷成型钢夹角的强度

获取原文

摘要

Thin-walled cold-formed steel (CFS) clip angles have been commonly used for connecting CFS framing members or attaching CFS members to the major building structure. The implementation of clip angles involves consideration of ultimate strength for combined bending moments and shear forces. Therefore, a test program of CFS clip angle was recently conducted to investigate the behavior and strength of cold-formed steel clip angle subjected to combined bending moments and shear forces at different boundary conditions. The research included connection tests on clip angle. The testing method was adopted from the AISI S914 Test Standard for Joist Connectors Attached to Clod-Formed Structural Framing. This paper presents the details of the test program, test results as well as recommendations for CFS clip angle configurations.
机译:薄壁的冷成型钢(CFS)夹子角度通常用于连接CFS构筑构件或将CFS成员连接到主要建筑结构。剪辑角度的实施涉及考虑组合弯曲时刻和剪切力的最终强度。因此,最近进行了CFS剪辑角的测试程序,以研究在不同边界条件下经受组合弯矩和剪切力的冷成型钢夹角的行为和强度。该研究包括对夹角的连接测试。从AISI S914测试标准中采用测试方法,用于连接到Clod形成的结构框架的托梁连接器。本文介绍了测试程序,测试结果以及CFS剪辑角度配置的建议的详细信息。