As many Water Resource and Recovery Facilities (WRRFs) across the United States face increasingly stringent effluent criteria, including Total Nitrogen, Total Residual Chlorine and Indicator Organisms, there is a need for a more rigorous and realistic approach for determining plant specific effluent total residual chlorine limits. This paper describes the development and application of a dynamic dilution and decay approach for re-calculating effluent TRC limits based on the actual processes that take place in the chlorine contact tank, the discharge pipe and the receiving water. This new approach was used to recalculate the effluent TRC limits for seven WWRFs, resulting in some plants having significantly higher effluent TRC limits.
机译:在美国的许多水资源和恢复设施(WRRF)面临越来越严格的污水标准,包括总氮,总残留的氯和指示器生物,需要一种更加严谨的和现实的方法来确定植物特异性流出物总残留氯限制。本文介绍了基于在氯接触罐,排放管和接收水中进行的实际过程重新计算污水TRC限制的动态稀释和衰变方法的开发和应用。这种新方法用于重新计算七种WWRF的污水TRC限制,导致一些具有明显较高的污水TRC限制的植物。