This paper researches distributed partial discharge detection technique synchronized with AC withstand voltage test of high voltage cable. Distributed partial discharge detection uses selective frequency current method and optical fiber and 3G technology to realize synchronous on-line monitoring of PD signal. There are suspected partial discharge defects in a XLPE power cable in Liaoning Province. Combining signal amplitude, frequency spectrum and time domain diagram, the defect is considered to be inside of GIS terminal. It is found that there are insulation defects on the surface of epoxy material after disassembling inspection, which is consistent with analysis results. It is considered that, the cable PD measurement synchronized with voltage withstand test has guiding significance for effectively evaluating cable construction and insulation.
机译:本文研究了与高压电缆交流耐电压试验同步的分布式局部放电检测技术。分布式局部放电检测使用选择性频率电流方法和光纤和3G技术实现PD信号的同步在线监测。辽宁省XLPE电力电缆涉及局部排放缺陷。组合信号幅度,频谱和时域图,缺陷被认为是GIS终端的内部。发现在拆卸检查后环氧材料的表面存在绝缘缺陷,这与分析结果一致。考虑到,与电压耐压同步的电缆PD测量具有用于有效评估电缆结构和绝缘的引导意义。