The simplified FEA method was proposed on tubesheet of fixed tubular heat exchanger with bellows expansion joints. Taking the waste heat recovery heat exchanger for example, the entire model and the simplified model were established using ANSYS software, and the calculation results of the key components of the two models were compared. The results show that distribution of TRESCA stress intensity and radial displacement of tubesheet for the simplified model are consistent with those of the whole model, but the stress of the simplified model is slightly larger than that of the entire model, so the result is conservative. It means that the simplified method is feasible. Meanwhile, application research on tubesheet of different kinds of heat exchanger was made using the simplified design method, it provides an efficient FEA method of the tubesheet design for heat exchanger with expansion joints.
机译:在具有波纹管膨胀接头的固定管状热交换器的管板上提出了简化的FEA方法。采用垃圾热回收热交换器,例如,使用ANSYS软件建立整个模型和简化模型,并比较了两种模型的关键部件的计算结果。结果表明,简化模型的TRESCA应力强度和管线径向位移的分布与整个模型的那些,但简化模型的应力略大于整个模型的压力,因此结果是保守的。这意味着简化的方法是可行的。同时,采用简化的设计方法对不同种类的热交换器的管板的应用研究,它提供了具有伸缩接头的热交换器管板设计的有效FEA方法。