首页> 外文会议>Asian Pacific Confederation of Chemical Engineering congress >Research of Temperature Distribution in Scrubbing-cooling Pipe in the New Type Scrubbing-cooling Chamber
【24h】

Research of Temperature Distribution in Scrubbing-cooling Pipe in the New Type Scrubbing-cooling Chamber

机译:新型擦洗冷却室中擦洗冷却管温度分布的研究

获取原文

摘要

New type scrubbing-cooling chamber is an important part of the new type coal-water slurry gasifier. In order to study temperature distribution in Scrubbing-cooling pipe in new type scrubbing-cooling chamber, a hot model equpiment is established. Measure the axis temperature along the pipe. Numeric models of temperature distribution and liquid-film flow in the pipe were established with the simulation software Fluent. The results indicated that there exists an optimal quench water quantity for given cooling effect and this water quantity could also simulation result. In the condition of optimal quench water quantity, the temperature decline regulation was found: most of temperature decline happened in the upper parts of the pipe, in the upper 0.2m height of the pipe, the temperature of syngas declined the severest. The temperature distribution simulation results are so well agreed with the experimental data that it can be given a guidance to the design of gasifier in industry.
机译:新型擦洗冷却室是新型煤水浆料气化炉的重要组成部分。为了在新型擦洗冷却室中的洗涤冷却管中研究温度分布,建立了热模型等价。沿管道测量轴温度。用仿真软件流畅建立了管道温度分布和液膜流量的数值模型。结果表明,给定冷却效果存在最佳的淬火水量,并且该水量也可以进行仿真结果。在最佳淬火水量的条件下,发现温度下降调节:在管道上的上部,管道上部发生的大部分温度下降,Syngas的温度下降最严重。温度分布仿真结果如此熟悉的实验数据,即它可以给予工业气化器设计的指导。