首页> 外文会议>Asian Pacific Confederation of Chemical Engineering congress >Research of Temperature Distribution in Scrubbing-cooling Pipe in the New Type Scrubbing-cooling Chamber
【24h】

Research of Temperature Distribution in Scrubbing-cooling Pipe in the New Type Scrubbing-cooling Chamber

机译:新型洗涤冷却室内洗涤冷却管温度分布的研究

获取原文

摘要

New type scrubbing-cooling chamber is an important part of the new type coal-water slurry gasifier. In order to study temperature distribution in Scrubbing-cooling pipe in new type scrubbing-cooling chamber, a hot model equpiment is established. Measure the axis temperature along the pipe. Numeric models of temperature distribution and liquid-film flow in the pipe were established with the simulation software Fluent. The results indicated that there exists an optimal quench water quantity for given cooling effect and this water quantity could also simulation result. In the condition of optimal quench water quantity, the temperature decline regulation was found: most of temperature decline happened in the upper parts of the pipe, in the upper 0.2m height of the pipe, the temperature of syngas declined the severest. The temperature distribution simulation results are so well agreed with the experimental data that it can be given a guidance to the design of gasifier in industry.
机译:新型洗涤冷却室是新型水煤浆气化炉的重要组成部分。为了研究新型洗涤冷却室内洗涤冷却管内的温度分布,建立了热模型设备。测量沿管道的轴温度。使用仿真软件Fluent建立了管道中温度分布和液膜流动的数值模型。结果表明,对于给定的冷却效果,存在最佳的淬火水量,该水量也可以作为模拟结果。在最佳淬火水量的条件下,发现了温度下降的规律:温度下降大部分发生在管道上部,在管道上部0.2m高度,合成气温度下降最为剧烈。温度分布模拟结果与实验数据吻合得很好,可为工业气化炉的设计提供指导。