首页> 外文会议>IEEE International Underwater Technology Symposium >Diagnostic evaluation of quay wall using three-dimensional acoustic measurement systems
【24h】

Diagnostic evaluation of quay wall using three-dimensional acoustic measurement systems

机译:使用三维声学测量系统Quay壁的诊断评估

获取原文

摘要

We used two types of acoustic measurement systems to assess the state of quay wall. Collapse and subsidence of quay wall at a harbor are often reported and a diagnosis method to prevent the accident has become a significant concern. The collapse is mainly occurred by air hole inside the quay wall. Therefore, the more robust and accurate diagnosis system is required and we try to apply the new diagnosis system which enables to assess the both inside and outside states of the quay wall from the underwater site. In the present study, two types of acoustic measurement systems using dual frequency identification sonar (DIDSON), and narrow-beam parametric sub-bottom profiler (SES2000) are applied to assess the both inside and outside states of quay wall. The field experiment was performed at the Iwanai port in Hokkaido, Japan (42° 59' N, 140° 30' E). The DIDSON was used generation of image mosaic and tree-dimensional image of the surface of quay wall. The SES2000 was created acoustic profile of inside the quay wall. The outside and inside acoustic images of the damaged quay wall were reconstructed from the collected data of DIDSON and SES2000. We detected corrosion hole. In addition, we detected corrosion holes and aged deterioration at other survey points using these two- and three-dimensional images. The state of the quay wall was quantified and compared with the results of direct measurement by diver. We should take more data in various field conditions and the continuous work with the proposed methods is needed for the practical use of them.
机译:我们使用两种类型的声学测量系统来评估码头墙的状态。倒塌和码头墙的沉降经常报道,并进行诊断方法,以防止事故成为一个重要的问题。倒塌主要是码头内的空气孔发生。因此,需要更强大和准确的诊断系统,我们尝试应用新的诊断系统,这使得能够从水下站点评估码头墙的内外状态。在本研究中,应用了使用双频识别声纳(DIDSON)和窄束参数分底分析器(SES2000)的两种类型的声学测量系统以评估码头墙的内部和外部状态。现场实验是在日本北海道的Iwanai港口进行的(42° 59'n,140° 30'e)。 Didson被用作码头墙体表面的图像马赛克和树尺寸图像。 SES2000是在码头墙内创建声学轮廓。损坏的码头墙的外部和内部声学图像从收集的DIDSON和SES2000的数据重建。我们检测到腐蚀孔。此外,我们使用这些两维图像检测在其他调查点处的腐蚀孔和老化劣化。码头墙的状态量化并与潜水员直接测量结果进行了比较。我们应该在各种现场条件下采取更多数据,并且需要与所提出的方法进行连续工作以进行实际使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号