首页> 外文会议>International Symposium on Water Resource and Environmental Protection >Measured humic acid in water by the potassium permanganate oxidation flow-injection chemiluminescence
【24h】

Measured humic acid in water by the potassium permanganate oxidation flow-injection chemiluminescence

机译:通过高锰酸钾氧化流动注射化学发光测量水中的腐殖酸

获取原文

摘要

When potassium permanganate oxidized humic acid, it has been discovered that they happened chemiluminescence reaction. Kinetic curve of system of KMnO4-humic acid is mapped and the reactions' conditions are optimized. Meanwhile, a new method of chemiluminescence analysis of determination of humic acid in natural water, and linear range of the method is 1×10−1∼1×102mg/L (R=0.9989) and the detection limit is 8×10−8g/ml. Doing parallel determination eleven times at the concentration of 20mg/L humic acid, finds that the relative standard deviation of RSD is 2.98%.
机译:当高锰酸钾氧化腐殖酸时,已经发现它们发生了化学发光反应。 KIMNO 4 -humic acid系统的动力学曲线映射,并优化了反应的条件。 同时,一种新的化学发光分析方法的天然水中腐殖酸的测定,以及该方法的线性范围是1× 10 − 1 ∼ 1× 10 2 mg / l(r = 0.9989)和检测限为8× 10 − 8 g / ml。 在20mg / L培养酸的浓度下进行平行测定11次,发现RSD的相对标准偏差为2.98%。