The RFSP-IST/CERBERUS [1] simulations are conducted with RRS on in order to be applied for various accident analyses of CANDU 6 reactors, such as, LBLOCA, SBLOCA, In-CORE LOCA, LOR and moderator accidents. The steady-state initial conditions are set by coupling with the thermalhydraulic code CATHENA [2], so that the initial conditions for the other important accident scenarios, e.g., LBLOCA, could also be established based upon the history of RRS actions that realistically follow the reactor operations. The representative cases studied here are selected in application to the moderator drain accidents, which demand the soundness and reliability of RRS predictions that show the capability of coping with the appreciable top-to-bottom flux tilts during the progress of transients. The CANDU 6 RRS algorithm requires a minimal time-step size of Δt=0.5 s that corresponds to the bulk control temporal sequences. An attempt has been made to double the time-step size to Δt=1.0 s. The results so obtained are compared against the simulation results that are obtained by using Δt=0.5 s.
机译:RFSP-IST / CERBERUS [1]模拟是用RRS进行的,以便应用于CANDU 6反应器的各种事故分析,例如Lbloca,SBLOCA,核心基因座,LOR和主持人事故。通过与热氢化术代码Cathena [2]耦合来设定稳态初始条件,使得其他重要事故情景(例如Lbloca)的初始条件也可以基于现实遵循的RRS动作的历史来建立反应堆操作。这里研究的代表性案例在应用于主持人漏极事故中,这需要RRS预测的声音和可靠性,其显示在瞬态进度期间与可观的顶到底磁通倾斜的能力。 CANDU 6 RRS算法需要最小的时间步长ΔT= 0.5秒,其对应于批量控制时间序列。已经尝试将时间步长到ΔT= 1.0秒的尝试。如此获得的结果与通过使用Δt= 0.5秒获得的模拟结果进行比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号