INTERFERENCE OF AN IMPRESSED CP SYSTEM WITH AN ADJACENT SACRIFICIAL CP SYSTEM AND ITS MITIGATION

机译:邻近牺牲CP系统的深入印象CP系统的干扰及其缓解

获取原文

摘要

An existing impressed CP system of steel tanks was found to be interfering with newly installed zinc anodes of an adjacent Pre-stressed Concrete Cylinder Pipeline. The interference prevented the zinc anodes from providing protection current. The two protected structures are electrically bonded. Field measurements showed that some zinc anodes were providing current. Other anodes acted as if receiving current from the pipes. The latter was thought to be a cause of accelerated pipe corrosion (reversed circuit). The tank bottom plates were also found to have lost protection. In this paper, analysis of field data revealed that all of the zinc anodes in the vicinity of the tanks were picking up stray current. A mitigation measure was proposed to remove the existing resistive bond between the two structures and install a few zinc anodes at the discharge area. An experimental approach was undertaken to determine the effectiveness of this method by simulating the problem on a lab scale. Experimental measurements showed that installing zinc anodes at the discharge area successfully prevented the current discharge from the pipe. It might therefore be possible to operate the two CP systems separately.
机译:发现现有的钢罐印模的CP系统是干扰相邻的预应力混凝土汽缸管道的新安装的锌阳极。干扰阻止了锌阳极提供保护电流。两个受保护的结构电键合。场测量表明,一些锌阳极提供电流。其他阳极作用于从管道接收电流。后者被认为是加速管道腐蚀(反转电路)的原因。还发现罐体底板损失保护。在本文中,分析现场数据的分析显示,罐附近的所有锌阳极都在拾取杂散电流。提出缓解措施以消除两种结构之间的现有电阻键,并在放电区域安装一些锌阳极。采用实验方法来确定该方法通过模拟实验室规模问题的有效性。实验测量表明,在放电区域安装锌阳极成功地防止了从管道排出的电流。因此,可以单独操作两个CP系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号