EROSION OF HERMETICALLY SEALED CONTACTS SUBJECT TO CABLE DISCHARGES

机译:受电缆放电的密封接触侵蚀

获取原文

摘要

Earlier investigations concerning erosion and arc duration for cable discharges are here supplemented by further experimental results, which are concerned particularly with the statistical distribution of the arc duration. If closure processes without visible arcs (time resolution approx. 10 ns) are disregarded, the arc duration is generally very well described by a log-normal distribution. The absolute values of the arc duration depend both on the battery voltage and, particularly, on the current. The very strong voltage dependence of the average arc duration and also of the material transfer rate observed in the earlier investigations for reed contacts with AgPd contact scheme may well be due to the superposition of the two processes "closure without arcs" and "closure with arc discharges".
机译:关于有关电缆放电的侵蚀和电弧持续时间的早期调查在这里补充了进一步的实验结果,特别是涉及电弧持续时间的统计分布。 如果忽略了没有可见电弧的闭合过程(时间分辨率约为10 ns),则弧形持续时间通常通过对数正态分布非常良好地描述。 电弧持续时间的绝对值取决于电池电压,特别是在电流上取决于电池电压。 平均电弧持续时间和在早期研究中观察到的具有AGPD接触方案的簧片触点的平均电弧持续时间的非常强大的电压依赖性可能是由于两个过程的叠加为“封闭弧”和“带电弧关闭” 排放“。