首页> 外文会议>International PUMP Users Symposium >The Effect of Foundation Piers on the Natural Frequencies of a Vertically Mounted Sewage Pump in Resonance with Vane Pass Excitations - (PPT)
【24h】

The Effect of Foundation Piers on the Natural Frequencies of a Vertically Mounted Sewage Pump in Resonance with Vane Pass Excitations - (PPT)

机译:基础墩对叶片谐振振荡共振垂直安装污水泵的自然频率的影响 - (PPT)

获取原文

摘要

After the recommended fixes were implemented, the vibration levels decreased from 0.6 in/s RMS to less than 0.2 in/s RMS at the bearing tower. Follow up field test by others showed that the frequencies that were at 38 Hz had shifted to 46Hz and 52.5Hz, close to analysis predictions.
机译:在实施建议的修复之后,振动水平在轴承塔上从0.6 in / s rms降低至小于0.2英寸/ s的rms。 通过其他人跟进现场测试表明,38 Hz的频率已移至46Hz和52.5Hz,接近分析预测。