Calculation of dosimetry parameters for 192Ir and 125I brachytherapy sources using Geant4

机译:使用GEANT4计算Sup> 192 IR和 125 i近距离放射治疗来源的剂量测定参数

获取原文

摘要

In brachytherapy cancer treatments, methods for calculation of dose delivered to tumours and organs have been continuously improving. Monte Carlo methods are na important tool in dose calculation for brachytherapy cancer treatments, where the exposition to the source planning aims at the maximization of dose deposition in the target volume, while minimizing the deposition in healthy tissues. The use of interstitial brachytherapy sources follows the recommendations of AAPM REPORT No.51. The present work is based on Monte Carlo simulations with the Geant4 toolkit of the dose quantities recommended by that report. An Iridium-192 Buchler HDR source and an Iodine-125 LDR source were simulated and the geometry of dose deposition in media and energy spectra have been obtained. Calculations also include the Dose Rate Constant Λ, the Geometry Factor G(r,θ), the Anisotropy Function F(r, θ) and the Radial Dose Function g(r, θ).
机译:在近距离放射治疗的癌症治疗中,递送给肿瘤和器官的剂量的方法一直不断改善。 Monte Carlo方法是Na重要的工具在近距离放射治疗癌症治疗的剂量计算中,源计划的阐述旨在最大化靶体积中的剂量沉积,同时最小化健康组织中的沉积。 间隙近距离放射治疗来源的使用遵循AAPM报告第51号的建议。 本作本作基于Monte Carlo模拟,其中包含该报告推荐的剂量数量的Geant4工具包。 模拟了铱-192Uchler HDR源和碘-125LDR源,并获得了介质和能谱中剂量沉积的几何形状。 计算还包括剂量率常数Λ,几何因子g(r,θ),各向异性函数f(r,θ)和径向剂量函数g(r,θ )。