首页> 外文会议>SPE/IATMI Asia Pacific Oil and Gas Conference and Exhibition >VSD Setting: ESP Motor Current-Feedback, An Effective Approach to Mitigate High Gas Interference Problem in Gassy ESP Well - Case Study SK-0178
【24h】

VSD Setting: ESP Motor Current-Feedback, An Effective Approach to Mitigate High Gas Interference Problem in Gassy ESP Well - Case Study SK-0178

机译:VSD设置:ESP电机电流反馈,一种有效的方法来缓解高气体干扰问题的气相研究SK-0178

获取原文

摘要

Gas Interference is one of the main difficulties in ESP Operation. High gas interference might reduce the pump volumetric efficiency (lower liquid production) and in the worst situation might stop the pump operation due to Gas Lock. In longer operation, it might even damage the motor due to frequent start-stop. ESP at SK-0178 installed in Nov-2016, and directly having problem with High Gas Interference & Gas lock (frequent underload alarm) resulting 3-4 times shutdown daily. Several troubleshooting steps have been taken: 1. Venting the annulus gas: Resulting no shutdown, could handle the gas issue but not an environmentally friendly solution and wasting valuable gas production (200 KSCFD); 2. VSD - PIP (Pump Intake Pressure) feedback: Resulting no shutdown, but ESP operated with fluctuating load and with lower production rate (gas interference, dropped by 40-60 BOPD). Detailed discussion with technology provider and reference case study come up with a proposal to trial New VSD Logic: Motor Current Feedback. The logic worked immediately after it is applied. All pump parameters (Frequency-Hz, Motor Load-A, PIP-Psig) shortly monitored to be stable unlike the previous PIP-feedback mode. The logic works better for high gas interference condition. It keeps the pump from having an accumulated gas inside the impeller-diffuser, hence preventing the pump from the possibility of having gas lock condition. Well test performed after the mode-change also showing a return to normal production. In longer monitoring period, the pump also showing a stable operation, thus we can say the approach is successfully mitigating the high gas interference ESP case in SK-0178: No shutdown, saving 200-KSCFD gas and 120-BOPD production.
机译:气体干扰是ESP操作中的主要困难之一。高气体干扰可能降低泵体积效率(较低的液体生产),并且在最坏情况下可能会因气体锁而阻止泵运行。在较长的操作中,由于频繁的起动,它可能会损坏电机。 ESP在2016年11月安装的SK-0178,并直接出现了高气体干扰和气体锁(频繁承保警报),导致每天3-4次关闭。已经采取了几个故障排除步骤:1。通风环状气体:没有关闭,可以处理气体问题,但不是环保的解决方案和浪费宝贵的天然气生产(200 kscfd); 2. VSD - PIP(泵进气压力)反馈:没有关闭,但ESP随着波动负荷和生产率较低(气体干扰,40-60次掉落)运行。与技术提供商的详细讨论和参考案例研究提出了试用新的VSD逻辑:电机电流反馈。逻辑在应用后立即工作。与先前的PIP反馈模式不同,所有泵参数(频率-Hz,电机负载-A,PIP-PSIG)都很快被监视为稳定。逻辑适用于高气体干扰条件更好。它保持泵在叶轮 - 扩散器内部具有累积的气体,因此防止泵免于具有气体锁定状态的可能性。在模式发生后进行的井测试也显示出恢复正常生产。在更长的监测期间,泵也显示出稳定的操作,因此我们可以说该方法在SK-0178中成功地减轻了高气体干扰ESP案例:无关断,节省200-KSCFD气体和120-BoPD生产。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号