首页> 外文会议>International Symposium on Advanced Mechanical Engineering;International Conference on Quality in Research >Heat Transfer Coefficient on Two-Phase Flow in Small Tube with Propane Iso-Butane Mixture Refrigerant
【24h】

Heat Transfer Coefficient on Two-Phase Flow in Small Tube with Propane Iso-Butane Mixture Refrigerant

机译:用丙烷ISO-丁烷混合物制冷剂的小管中两相流量的传热系数

获取原文

摘要

Refrigerants in the evaporator have an important role in absorbing heat in the refrigeration system. However, the halocarbon refrigerants usage could damage the layer of ozone and causing global warming. Natural refrigerant is being developed to overcome the negative effects of using halocarbon refrigerants. MC-134 is one of natural refrigerant, a hydrocarbon refrigerant, that the main substances components are propane and iso-butane. This research will discuss the heat transfer coefficient value of MC-134 and the characteristics that affecting its value. The refrigerant is circulated in a heated pipe with 0.5 mm in diameter and 0.5 m in length. The result of the experiment is the variation of heat transfer coefficient between 678.42 - 5366.19 Watt/m~2.°C. The value is determined by the heat flux at 149.3 - 7441.9 Watt/m~2, the mass flux at 39 - 878.5 kg/m~2.s, and the quality of vapor at 0.004 - 0.065. This research also shows that increasing heat flux will increase the heat transfer coefficient value.
机译:蒸发器中的制冷剂在制冷系统中吸收热量方面具有重要作用。然而,卤代碳制冷剂使用可能会损坏臭氧层并导致全球变暖。正在开发天然制冷剂以克服使用卤代烃制冷剂的负面影响。 MC-134是天然制冷剂,烃制冷剂之一,主要物质成分是丙烷和异丁烷。该研究将讨论MC-134的传热系数值和影响其值的特性。制冷剂在加热管中循环,其直径为0.5mm,长度为0.5米。实验结果是678.42-5366.19瓦/ m〜2.℃的传热系数的变化。该值由149.3-7441.9瓦特/ m〜2的热通量决定,质量通量在39-878.5 kg / m〜2中,蒸汽质量为0.004-0.065。该研究还表明,增加的热通量会增加传热系数值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号