Preliminary investigation of the robustness of a fluorescent measuring system for in-line and real-time monitoring of blood-_pH in extracorporeal circulation

机译:初步调查荧光测量系统的鲁棒性,在体外循环中血液_PH的直线实时监测

获取原文

摘要

The possibility to monitor blood-pH has long been acknowledged to provide significant information for the diagnosis, management and treatment of a variety of diseases and it would be of considerable support for the administration of several treatments such as, for example, extracorporeal (blood) circulation (ECC). During ECC, the patient's blood flows outside the body in disposable bloodlines and devices for treatments such as blood purification or circulation/ventilation/oxygenation support. Although blood-pH can be measured since the early twentieth century by using ion-sclectivc electrodes (ISEs) and, more recently, also by using point-of-care testing (POCT) instruments, nowadays no measurement method has fully succeeded in providing a cost-effective, reliable and accurate estimate of the blood-pH to be routinely used for its real-time monitoring. In a recent paper, we have proposed and demonstrated a measuring instrument for the in-line and real-time monitoring of blood-pH during ECC. Such a measuring system consists of a low-cost fluorescent disposable sensor that can be integrated into the bloodline and, of a non-disposable reading system that interrogates the sensor without contacting the patient's blood. In this paper, we investigated the robustness of such a measuring system to variations of blood parameters such as blood flow and hematocrit. The obtained results demonstrate that, although during the tests the pH, flow, and hematocrit values were significantly varied - pH from ≈ 6.8 pH, to ≈ 7.4 pH; hematocrit from 32%, to 40%: flow from 250 ml/min, to 400 ml/min, - the measuring system continued to guarantee a measurement error inferior to ±0.04 pH, thus complying with the metrological requirements for in-line and real-time monitoring of blood-pH during ECC.
机译:长期以来,监测血液pH的可能性已经承认为各种疾病的诊断,管理和治疗提供了重要信息,并且对若干治疗的给药是相当大的支持,例如体外(血液)循环(ECC)。在ECC期间,患者的血液在一次性血统和装置外部流动,用于血液净化或循环/通气/氧合载体等处理。虽然自二十世纪早期通过使用离子Sclectivc电极(ISE)可以测量血液pH,但最近也通过使用护理点测试(POCT)仪器,如今,没有测量方法完全成功提供a经常使用的血液pH经常用于其实时监测的成本效益,可靠和准确的估计。在最近的一篇论文中,我们已经提出并展示了ECC期间血液pH的直接和实时监测的测量仪器。这种测量系统由低成本的荧光一次性传感器组成,可以集成到血线中,并且在不接触患者血液的情况下询问传感器的非一次性读取系统。在本文中,我们研究了这种测量系统的稳健性,以血流和血液比素种植体如血液参数的变化。所得结果表明,尽管在测试期间pH,流动和血细胞比容值显着变化 - pH从≈3.8pH,至≈4pHpH;血细胞比容从32%,至40%:流量从250毫升/分钟,至400毫升/分钟, - 测量系统继续保证测量误差较差±0.04 pH,因此符合在线和实际的计量要求 - ECC期间对血液pH的时间监测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号