首页> 外文会议>International RILEM Workshop on Concrete Durability and Service Life Planning >Effect of Alite Content in Sulphate-Resistant Cement on Heat Release in Massive Hydraulic Engineering Structures
【24h】

Effect of Alite Content in Sulphate-Resistant Cement on Heat Release in Massive Hydraulic Engineering Structures

机译:硫酸盐含量在硫酸盐水泥上对大规模液压工程结构中热释放的影响

获取原文

摘要

The heat release of cement affects the quality and speed of concrete works,the implementation of the construction project management,and the durability of concrete structures,especially for massive hydraulic structures,in a construction of which sulfate-resistant cement is often used [1].The greatest amount of heat is released during hydration of tricalcium aluminate C3A and tricalcium silicate-alite C3S.At the same time,the Interstate Standard GOST 22266-2013 on sulfate-resistant cement normalizes only the limit value of C3A content(<3.5%)in mineralogical composition,when there are no special requirements to C3S content.Some thermo mechanical and thermo physical concrete properties depending on the ambient temperature,the amount of heat generated,and the mineralogical composition of sulfate-resistant cement coming from cement plants for the Rogun HPP construction are presented.
机译:水泥的热释放影响了混凝土作品的质量和速度,建设项目管理的实施,以及混凝土结构的耐久性,特别是对于大规模液压结构,在耐硫酸盐水泥的结构中经常使用[1] 。铝铝酸钙C3A和硅酸钙硅酸钙的水合过程中最大的热量是释放的,同时,耐硫酸盐水泥上的州间标准GOCT 22266-2013仅使C3A含量的极限值标准化(<3.5% )在矿物学组合物中,当C3S含量没有特殊要求时。有些热机械和热物理混凝土特性取决于环境温度,产生的热量和来自水泥厂的耐硫酸盐水泥的矿物质组成。 罗云惠普建设展出。