首页> 外文会议>Joint Meeting of the Bioelectromagnetics Society and the European BioElectromagnetics Association >Non-sinusoidal magnetic field exposure: Comparison of time domain assessment methods proposed in the Non-binding guide for practical implementation of EU directive 2013/35/EU
【24h】

Non-sinusoidal magnetic field exposure: Comparison of time domain assessment methods proposed in the Non-binding guide for practical implementation of EU directive 2013/35/EU

机译:非正弦磁场曝光:在欧盟指令2013/35 /欧盟的实际实施指南中提出的时域评估方法的比较

获取原文

摘要

Non-sinusoidal magnetic fields at common workplaces were measured and exposure was comparatively assessed by the Weighted Peak Method in time domain (WPM-TD) and an alternative time domain assessment method (TDA method) published in the non-binding guide for practical implementation of the "workers directive" 2013/35/EU. It could be demonstrated that the TDA method systematically and substantially (up to 11.7 dB) underestimates exposure compared to the WPM-TD (indicated as the reference method in 2013/35/EU). We therefore recommend to remove this method from the non-binding guide as soon as possible.
机译:测量共同工作场所的非正弦磁场,并通过时域(WPM-TD)中的加权峰值方法和替代时域评估方法(TDA方法)进行相对评估的,在非绑定指南中进行实际实施“工人指令”2013/35 /欧盟。可以证明与WPM-TD相比,系统且基本上(最多11.7dB)的TDA方法低估了暴露(在2013/35 / 35 /欧盟的参考方法)。因此,我们建议尽快从非绑定指南中删除此方法。