首页> 外文会议>Biennial International Conference on Power and Energy Systems >A Critical Analysis of Power Quality Issues in Data Center
【24h】

A Critical Analysis of Power Quality Issues in Data Center

机译:数据中心电能质量问题的关键分析

获取原文

摘要

Data Center in electrical power system is used to record and store all the activities in the power system network. Data center have the Information Technological (IT) equipment Power Supply Unit (PSU) to process the power system data. Uninterrupted power supply (UPS) unit required for powering IT equipment PSU. IT equipment PSU and UPS absorbs more reactive current and inject harmonic current into the power system network. This paper analyses the Power Quality issues of IT equipment PSU and UPS used in the Data Center. This paper also give a suggestion for mitigation of harmonics present in the data Center.
机译:电力系统中的数据中心用于记录和存储电力系统网络中的所有活动。数据中心具有信息技术(IT)设备电源单元(PSU)来处理电力系统数据。供电IT设备PSU所需的不间断电源(UPS)单元。 IT设备PSU和UPS吸收更多的反应电流并将谐波电流注入电力系统网络。本文分析了数据中心中使用的IT设备PSU和UPS的电力质量问题。本文还提出了缓解数据中心存在的谐波的建议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号