【24h】

A critical analysis of Power Quality issues in Data Center

机译:数据中心电能质量问题的关键分析

获取原文
获取原文并翻译 | 示例

摘要

Data Center in electrical power system is used to record and store all the activities in the power system network. Data center have the Information Technological (IT) equipment Power Supply Unit (PSU) to process the power system data. Uninterrupted power supply (UPS) unit required for powering IT equipment PSU. IT equipment PSU and UPS absorbs more reactive current and inject harmonic current into the power system network. This paper analyses the Power Quality issues of IT equipment PSU and UPS used in the Data Center. This paper also give a suggestion for mitigation of harmonics present in the data Center.
机译:电力系统中的数据中心用于记录和存储电力系统网络中的所有活动。数据中心具有信息技术(IT)设备电源单元(PSU),用于处理电源系统数据。为IT设备PSU供电需要不间断电源(UPS)单元。 IT设备PSU和UPS吸收更多的无功电流,并将谐波电流注入电力系统网络。本文分析了数据中心中使用的IT设备PSU和UPS的电能质量问题。本文还提出了减轻数据中心中存在的谐波的建议。