摘要

The paper, prepared by CIGRE WG D1.25, presents the experience in practical application of sensitivity verification of the UHF partial discharge detection system for GIS after its introduction in 1999 by CIGRE. A detailed description of the two-step procedure, Step 1 in laboratory and Step 2 on-site, is given and supported by examples. Guidelines will help manufacturers and users in the effective application of the UHF method for PD detection on GIS and will permit to avoid technical misinterpretations. The procedure is described in detail in CIGRE Technical Brochure No. 654.
机译:由CIGRE WG D1.25制备的纸张介绍了1999年通过CIGRE引进了GIS的UHF局部放电检测系统的敏感性验证的实际应用的经验。通过实施例给出并支持两步步骤,步骤1,在实验室和步骤2中的步骤1的详细描述。指南将帮助制造商和用户在GIS上有效应用UHF方法进行PD检测,并允许避免技术误解。该程序在CIGRE技术手册No.654中详细描述。