Currently, most of the boilers in power plant are designed by the heat balance based on first law of thermodynamics only, and it analyses the condition of using energy from the perspective of quantity of energy. However, The real energy utilization should be justified not only from the quantity but also from the quality, because the quality of energy based on second law of thermodynamics can reflect the irreversibility in processes and components. In order to revealing the real energy losses, we must establish exergy analysis model of 130t/h Biomass-Fired Boiler. This article calculates the exergy losses of all kinds of boiler surface and the overall exergy efficiency of boiler, together with exergy distribution characters analysis result of 130t/h Biomass-Fired Boiler. The results obtained open out the greatest exergy loss and the place to generate these losses of boiler, and provide scientific gist for improving utilization of boiler energy.
机译:目前,电厂的大多数锅炉仅基于第一热力学定律的热平衡设计,并从能量数量的角度分析了使用能量的条件。然而,实际能量利用不仅应该从数量而且来自质量的数量,因为基于第二种热力学定律的能量质量可以反映过程和部件的不可逆转性。为了揭示真实的能量损失,必须建立130T / H生物量燃烧锅炉的Deerteny分析模型。本文通过130t / h生物量燃烧锅炉,计算各种锅炉表面和锅炉总体漏洞效率的漏洞。结果取得了最大的丧失丧失和产生这些锅炉损失的地方,提供了改善锅炉能量利用的科学专家。