首页> 外文会议>IEEE PES TD Conference and Exposition >Recommended test methods for underground power cables containing superabsorbent materials
【24h】

Recommended test methods for underground power cables containing superabsorbent materials

机译:包含超吸收材料的地下电缆的推荐试验方法

获取原文

摘要

This paper recommends new test media and methods for underground power cables with superabsorbent water swelling materials (SAP). The tests should reflect actual service conditions in the field. The type of water chosen for swelling tests should have ionic content to reflect the composition of actual soil water. The cable tests should also reflect actual conditions. The tests should measure the performance of the cable under simulated thermo-mechanical loading conditions, under water pressure at the operating voltage. The testing should highlight the water-blocking performance of the SAP in its functional state, that is, in the form of a hydrated gel. Such requirements are already a part of International Electrotechnical Commission (IEC) test methods and are also a requirement for certain Insulated Cable Engineers Association (ICEA) test methods thereby allowing harmonization of the global requirements for water-blocked cables.
机译:本文建议使用超吸收性水膨胀材料(SAP)的地下电缆的新测试介质和方法。测试应反映现场的实际服​​务条件。选择用于溶胀试验的水的类型应具有离子含量以反映实际土壤水的组成。电缆测试还应反映实际情况。测试应在模拟热机械负载条件下测量电缆的性能,在水压下在工作电压下。该测试应突出液体堵塞在其功能状态下的水堵塞性能,即以水合凝胶的形式突出。这些要求已经是国际电工委员会(IEC)测试方法的一部分,也是某些绝缘电缆工程师协会(ICEA)测试方法的要求,从而允许协调防水电缆的全球要求。