摘要

Through methods, such as microscope analysis, chemical analysis, metallography examination and scanning electron microscope etc, the causes resulting in high temperature reheater tube cracking of station boiler have been analyzed. The result indicates the crack is reheat crack, and structure stress, higher hardness and excessive welding residual stress are the primary inducement of tube joint crack.
机译:通过诸如显微镜分析,化学分析,金相检查和扫描电子显微镜等方法,已经分析了导致电站锅炉高温再热管破裂的原因。结果表明裂缝是再加热裂缝,结构应力,更高的硬度和过度焊接残余应力是管接头裂纹的主要诱导。