首页> 外文会议>Advanced polymer processing international forum >Simulation Study for the Effects of Clearance Volume on Full Metal Single Screw Pump Performance
【24h】

Simulation Study for the Effects of Clearance Volume on Full Metal Single Screw Pump Performance

机译:间隙对全金属单螺杆泵性能影响的仿真研究

获取原文

摘要

The stators and rotors of full metal screw pump take way of clearance fit, so the clearance value will directly affect the pump lifting performance and efficiency. Firstly using the finite volume method to establish a full-metal single screw pump 3D model, secondly using FLUENT software to calculate outlet pressure changes with different series of clearance value between the stator and the rotor of the pump in condition of the same inlet pressure .lastly Drawing outlet pressure change curves to evaluate the concrete effect of clearance volume on the performance of the pump. The results indicate that the pump outlet pressure increased first and then decreased with increasing clearance value and that pump has good lifting oil capacity with clearance value which is less than 0.5mm.
机译:全金属螺杆泵的定子和转子采用间隙合适,因此间隙值将直接影响泵提升性能和效率。首先使用有限体积法建立一个全金属单螺杆泵3D模型,其次使用流畅的软件计算出口压力变化,在定子与泵的转子之间的不同系列间隙变化,在相同的入口压力的状态下。最后引进出口压力变化曲线,以评估间隙上限对泵性能的混凝土效应。结果表明泵出口压力首先增加,然后随着空隙值的增加而降低,并且泵具有良好的提升油容量,间隙值小于0.5mm。