Analysis of Coated-after Superheater Pipe Bursting Accident in Utility Boiler

机译:公用事业锅炉中涂层过热器管道爆破事故分析

获取原文

摘要

Pipe failure accidents (bursting) are frequent in thermal power plants, and severely mfluence the safe and economic running of power generation units. The authors analyzed the possible causes and features of coated-after superheater pipe bursting in boilers. Taking the coated-after superheater pipe bursting accident in a power plant for an example, the authors conducted macroscopic topography analysis, running environment analysis, metallurgical analysis, chemical composition analysts and strength analsis of the bulged pipe, ruled out mat the coated-after superheater pipe basting was caused by superheating, and demonstrated that the bursting was caused by crack defect that had not been found during regular inspection.
机译:管道故障事故(爆破)在火电厂频繁频繁,严重影响发电单位的安全和经济运行。作者分析了锅炉中涂布过过热器管道的可能原因和特征。采用涂层后的超级泡沫管道在发电厂中发生爆破事故,为一个例子,作者进行了宏观形貌分析,运行环境分析,冶金分析,化学成分分析师和凸出管道的强度肛门,排除了涂层后的过热器管道塑料是由过热引起的,并证明了突发是由尚未在定期检查期间发现的裂缝缺陷引起的。