首页> 外文会议>International Conference on Advances in Materials Science and Manufacturing Technology >Research on Function Real-time of Substation Automation System Based on IEC61850
【24h】

Research on Function Real-time of Substation Automation System Based on IEC61850

机译:基于IEC61850的变电站自动化系统功能实时研究

获取原文

摘要

The function real-time of substation automation system based on IEC61850 depends on the distribution mode of logical nodes, the processing speed of logical nodes and the communication delay between logical nodes. The realization principles of functions' free distribution are introduced based on IEC61850, take bus protection function and distributed interlock function examples, the functions are deposed into the connection diagram of logical nodes and their communication events are introduced in great detail. The simulation models of D2 substation which has unified network or two-tier network are established with OPNET. The communication events of bus bar protection function and distributed interlock function are simulated and analyzed based on this mode. The rationality of distribution mode of system's functions is quantitative analyzed which provide guidance to improve the real-time performance of system's functions and network structure.
机译:基于IEC61850的变电站自动化系统的功能实时取决于逻辑节点的分发方式,逻辑节点的处理速度和逻辑节点之间的通信延迟。基于IEC61850介绍了函数自由分布的实现原则,乘坐总线保护功能和分布式互锁功能示例,该功能被归档为逻辑节点的连接图,并且它们的通信事件非常详细地引入。使用OPNET建立了具有统一网络或双层网络的D2变电站的模拟模型。基于此模式模拟和分析了总线栏保护功能和分布式互锁功能的通信事件。系统功能分布模式的合理性是定量分析,提供了提高系统功能和网络结构的实时性能的指导。