【24h】

Research on reflective ultrasonic CT experimental device

机译:反光超声CT实验装置研究

获取原文

摘要

In order to emphasize the significance of CT simulation and to help students to understand CT working principle, especially the graphic reconstruction principle, a reflection type ultrasonic CT experimental device based on the Stm32 is designed for the teaching of CT. The device consists of a transceiver ultrasonic module, a MCU module, a serial communication module, a 3D mechanical platform, a stepper motor drive module and a Matlab graphical reconstruction module. The ultrasonic signals are launched by the Stm32 MCU controlling transceiver ultrasonic module, the movements of the object under test and the rotation and translation of ultrasonic transducer are controlled by the VB interface. The signals reflected by the object under test will be collected and processed by the Stm32 MCU, and then transferred to a computer through a serial port communication. A 3-D contour graph reconstruction of the object under test is implemented by the Matlab software and is displayed in the VB interface imaging window. There are many advantages of this device, such as small volume, simple structure, widely-used components, easy maintenance and repair, and thus, broad market prospects.
机译:为了强调CT仿真的重要性,并帮助学生了解CT工作原理,特别是图形重建原理,基于STM32的反射式超声波CT实验装置专为CT的教学而设计。该设备包括收发器超声波模块,MCU模块,串行通信模块,3D机械平台,步进电机驱动模块和MATLAB图形重建模块。超声波信号由STM32 MCU控制收发器超声模块推出,所测物体的运动和超声换能器的旋转和翻译由VB接口控制。由被测物体反射的信号将由STM32 MCU收集和处理,然后通过串行端口通信传送到计算机。在测试中的对象的三维轮廓图重建由MATLAB软件实现,并显示在VB接口成像窗口中。该装置有许多优点,如体积小,结构简单,宽采的组件,易于维护和维修,从而实现广阔的市场前景。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号