An electrochemical sensor for the detection of Cu (II) ion is described by using poly (vinyl alcohol) (PVA) and carboxylic multi-walled carbon nanotubes (c-MWNT) modified glassy carbon electrode (GCE) by anodic stripping voltammetry (ASV). PVA/c-MWNT film greatly improves the sensitivity of determining Cu (II). The striping peak currents change linearly with the concentration of Cu (II) from 1.0×10~(-8) to 8.0×10~(-5) mol/L for an accumulation time of 200 s, correlation coefficient r = 0.9980. The detection limit is as low as 5.0×10~(-9) mol/L. The high sensitivity, selectivity, and stability of the PVA/c-MWNT film demonstrated its practical application.
机译:通过使用聚(乙烯醇)(PVA)和羧酸多壁碳纳米管(C-MWNT)改性玻璃碳电极(GCE)通过阳极溶出伏安法(ASV)来描述用于检测Cu(II)离子的电化学传感器。 PVA / C-MWNT薄膜大大提高了确定Cu(II)的灵敏度。条纹峰值电流随着Cu(II)的浓度为1.0×10〜(-8)至8.0×10〜(-5)mol / L的浓度为200秒,相关系数r = 0.9980的累积时间。检出限量低至5.0×10〜(-9)mol / l。 PVA / C-MWNT薄膜的高灵敏度,选择性和稳定性证明了其实际应用。